ExtremeStor PCI-e Expansion Chasis EX24 (SSD)

iNAS_12_SIDE.jpg “ExtremeStor™ expansion chassis with five additional PCI Express Gen2 slots via a x16 (80Gb/s) expansion cable.”
Globalstor’s ExtremeStor Expansion System allows system developers to expand one host x16 Gen2 PCI Express slot to an expansion chassis with five additional PCI Express Gen2 slots via a x16 (80Gb/s) expansion cable. The expansion chassis’ non-blocking eighty lane PCI Express Gen2 switch enables the coupling of cost-effective enterprise host PCs with high bandwidth, peer-to-peer capable I/O subsystems.The PCI Express Expansion System includes a host bus cable adapter, an expansion cable, and an expansion backplane mounted in an industrial 19-inch chassis. The PCIe-426 is a PCI Express Gen2 x16 Host Bus to Expansion Cable Adapter that use latency-free bus repeaters to bridge from the host bus to an x16 expansion cable of either one or three meters. The cable connects to the Expansion Chassis and the PCIe-427 Switched Expansion Backplane.

Features

  • 4U Height and 22 Inch Depth
  • Seven Full Length PCI Express Ports
  • Three 5.25 Inch External Drive Bays
  • Two 3.5 Inch Internal Drive Bay
  • Locking Drive Bay Door
  • 180 CFM Chassis Cooling
  • 650 or 1500 Watt Power Supply 100-240 VAc, 47-63 Hz Power Input
  • Regulatory Compliance – UL, CE Safety

 

Hardware and Technical Specifications

Dimensions and Weight
Unit weight: 140lbs. (63.5kg)
populated with 24 disk drives
Shipping weight: 170lbs. (77kg)
carton packaging
Shipping weight: 240lbs. (109kg)
Stereo 2K Certified  Stereo 4K Certified

Performance
2,000MBps sustained writes and up to 4,000MBps sustained read in RAID 5

Environmental Control
L.E.D. and Audio alarm for internal temperature monitoring

Power
Power supply: 1500 Watt PFC power supply unit
Input range: auto-sensing 100 to 240 VAC
Power source: (1) standard AC power cord

Cooling
Center of unit: (3) Hot-swap 120mm X 120mm X 38mm fans
Top of unit: (1) Fixed mount 80mm X 80mm X 38mm fan
Temperature: 0°C (32°F) – 50°C (122°F)
Humidity: 5% – 95% non-condensing
Advanced thermal design supports faster running SSD Disk

Base System Hardware
PCI Expansion Chassis
3 PCIe x16 slots (x16 speed)
2 PCIe X16 skits (x8 speed)
PCIe x16 daughter card
1 Meter PCI Expansion cable standard  (3 Meter Cable is optional)  
Optional Integrated RAID array (requires the use of 1 PCIe x8 slot) 

 

iNAS_12_SIDE.jpg iNAS_12_SIDE.jpg iNAS_12_SIDE.jpg iNAS_12_SIDE.jpg iNAS_12_SIDE.jpg